• MODELS HSG200 HSG400 A SCOTT FETZER COMPANY GAS BURNERS 801 GLASGOW AVE. FORT WAYNE, IN 46803 120V/50-60 HZ 220V/50 HZ PART NO. 62484-001B US PATENT NO.

Oct 01, 2016 Quemador a Gas para hornos de panaderias y calderas. Para usar en calderas, hornos de panaderia, hornos en general, calentadores de agua, Quemadores Wayne Peru. Tyler Perry Marriage Counselor Play. Quemador a gas Modelo HSG-400.

4,388,064 WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. • SPECIFICATIONS MODELS HSG200, HSG400 NATURAL OR PROPANE GAS NOTE: Dimensions in ( ) are informational only. Cara Sharing Internet Connection Windows Xp there.

English values take priority. HSG200 Maximum Input Capacity - 200 MBtu/HR (211000 kJ) Minimum Input Capacity - 60 MBtu/HR (63300 kJ) HSG400 Maximum Input Capacity - 400 MBtu/HR (422000 kJ) Minimum Input Capacity - 200 MBtu/HR (211000 kJ) SUPPLY LINE PRESSURE REQUIRED: Natural or Propane 5.5 W.C. • Power burner design makes the HSG200 and those required by this burner and that they are in HSG400 well suited for “negative draft” fired proper working order. • Pitch the horizontal run of the flue pipe upward 1/4 inch The draft control should be hood type per Figure 2 or, IF (6.35mm) per foot (.305m) or more.

Run directly to the APPROVED BY LOCAL AUTHORITIES, a single chimney, fasten joints securely and support horizontal barometric damper suitable for gas firing per Figure 3. COMBUSTION CHAMBER F. GAS PIPING NOTICE: All piping must comply with state and/or A combustion chamber is normally required to local codes. The available gas supply pressure protect non-heat transfer surfaces, and to provide a should be within minimum and maximum pressures radiant bed for rapid heat transfer to the primary shown in the burner specifications. • AND INSTALLATION The installation must be wired and GROUNDED in accordance with local codes or in their absence, The HSG200 and HSG400 power gas conversion with the National Electric Code ANSI/NFPA No. 70- burners are approved for use with natural and 1987 or latest edition.

• COMBINATION GAS VALVE approximately 2.0” W. Dell 1d3b Keygen Safe. C. (498.2Pa) to 4.0” W.C.

(996.4Pa) is factory set at 3.5” W.C (871.85Pa). The 24 VAC combination gas valve serves three (3) When pressure adjustment is required for setting functions: (1) manual gas shut-off, (2) main gas input capacity with a selected orifice from Figure 10, flame pressure regulator, (3) automatic electric remove the regulator cap for access to the slotted. • SECTION II INITIAL START UP 1. NOTE: Read applicable sequence the primary air damper open or closed to visually burner/primary gas control operation in obtain a blue flame with well defined orange or Section 3 Operation and Troubleshooting yellow tips for natural gas, or well defined yellow tips before proceeding.